Enforcer 2 Breathalyser kit, 0-0.40% BAC. This handheld unit is a reliable, easy to use breathalyser suitable for workplace use. It is Australian Standards approved and calibrated for Australian and New Zealand legal limit.
The Enforcer 2 Breathalyser is ideal for professional use, providing instantaneous digital %BAC (breath alcohol concentration) results. This Australian Standards approved model can be used as a breath alcohol screening device in the workplace by OH&S staff, by professional drivers or by health care professionals, however this unit is normally used as a personal breathalyser.
The Enforcer 2 Breathalyser is a dual-mode device: fast mode is used for rapid testing of a large volume of people indicating a "0" or "Hi" reading. Normal mode provides a specific digital readout eg. 0.05%BAC. This is the mode used for general public use or to obtain a more specific reading in the workplace. This is the default mode when the unit is turned on.
The Enforcer 2's Flow Control Technology means that the sensor checks the flow rate of your breath and must receive an adequate air sample before it will provide you with a reading. Intelli-sensor Recognition Technology checks the sensor condition every time you use your breathalyser. Stability of the sensor is analysed as well as the level of alcohol residue built-up on the sensor. An indication will be given if the sensor needs recalibration.
Features:
Accurate and easy to use
2 decimal place accuracy
Range of 0.00-0.40%BAC (8 x the legal limit)
Large digital display
Fast mode for rapid workplace testing
Australian Standards AS3547 approved
Self replaceable sensor module
Specifications:
Sensor Type: Semi-conductor Ethanol Sensor with Gas Flow Sensor built-in
SRS Technology
Accuracy: +/- 0.01% at 0.10% BAC
Accuracy Level: 4/5
Calibrated to Australian & NZ legal limit
Range: 0.00-0.40 %BAC
Display: 2 Decimal Places with Backlight
Usage Monitor: Cumulative test counter on start-up
Warm-up time: < 20 seconds
Breath Sampling Time: 3 seconds (approx.) Gas flow sensor ensures a minimum flow must be received to get a reading
Response time: Fast Mode < 2 seconds, Normal Mode < 5 seconds
Time Between Retests: < 4 seconds (Fast mode) < 20 seconds (Normal Mode)
Result Reading: Fast Mode: '0'=0.00-0.01 'Hi'=0.02-0.40 Normal Mode: 0.00-0.40
Temperature / Ambient conditions: Operation : 0 to 40°C Storage : 0 to 50°C
External Casing: Shock Resistant Plastic
Dimensions: 137 x 73 x 44mm
Weight: 115g with batteries
Power Source: 2 x 1.5v ‘AA’ Alkaline batteries
Power Usage: Over 200 times per set of batteries
Mouthpieces: 5 mouthpieces included, additional mouthpieces available on request